A. M. Albisser, B. S. Leibel, W. Zingg, C. K. Botz, E. B. Marliss et al., The development of an artificial endocrine pancreas and its application in research and clinical investigation The status of electrochemical sensors for in vivo glucose monitoring Enzyme electrode probes In Immobilized Enzymes , Antigens, Antibodies and Peptides: Electrode systems for continuous monitoring in cardiovascular surgery : A highly sensitive glucose electrode using glucose oxidase collagen film, Yellow Springs Instrument Go.: Instruction manual Y.S.I, model 23A, 1975. 6 Solea Tacussel: Provisional notice on Solea Engl. 1 Clark, L. C : Membrane polarographic electrode system and method with electrochemical compensation. U.S. Patent 3., and Gautheron, D. C. Enzyme collagen membrane tor electrochemical determination of glucose, pp.87-92, 1962.

G. Sensors-/, D. R. Thevenot, M. H. Keyes, F. E. Semersky, D. N. Gray et al., Glucose analysis utilizing immobilized enzymes 1: (4) 91 94 The enzyme electrode C : Resistance to deactivation of enzyme-collagen membrane Enzyme immobilization on activated carbon: alleviation of enzyme deactivation by hydrogen peroxide How fibroblasts and giant cells encapsulate implants: considerations in design of glucose sensors Differential anodic enzyme polarography for the measurement of glucose An enzyme electrode for the amperometric determination of glucose Enzyme electrode for glucose based on an iodine membrane sensor, Enzyme Microbiol. Technol . Nature Biochimie Biotechnol. Bioenerg. Diabetes Care Adv. Exp. Med. Biol. Anal. Chim. Acta, vol.214, issue.64, pp.986-88, 1967.

. Chim, W. Acta66, P. Racine, and P. Schlaepfer, Sensoren fur Lactat und Glucose, Ber. Busenges. Phys. Chem, vol.77, issue.3 21, pp.443-5510, 1973.

. Ger, H. M. Offen-aussaresses, R. Guillien, P. Nabet, G. G. Guilbault et al., Electrode a enzyme specifique du glucose basee sur a la detection amperometrique de l'hexacyanoferrate II Le dosage du glucose sanguin a l'aide d'une electrode a enzyme. A n n Enzyme electrode for glucose, Determination of glucose, urea and penicillin using enzyme-pH electrodes, pp.193-97, 1972.

M. Nanjo, G. G. Guilbault, G. J. Lubrano, G. G. Guilbault, C. Tran-minh et al., Enzyme electrode for l-amino acids and glucose, Enzymelektrode zur Bestimmung von Glucose. D D R Patent 123-125, pp.367-73, 1974.
DOI : 10.1016/S0003-2670(01)85473-8

C. , D. , A. L. Yao, S. J. , J. L. Froment et al., Immobilized enzyme electrodes for the potentiometric measurement of glucose concentration: immobilization techniques and materials 32 R o m e t t e Glucose-oxidase electrode. Measurements of glucose in samples exhibiting high variability in oxygen content A n enzyme electrode based on immobilized glucose oxidase, J. Biomed. Material Res. Clin. Chim. Acta In Ion and Enzyme Electrodes in Biology, vol.13, issue.2, pp.921-956, 1976.

F. R. Shu, W. , G. S. , W. , G. S. Bourgeois et al., Rotating ring-disk enzyme electrode for surface catalysis studies. Anal. C h e m Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer. Anal. C h e m Chemically modified electrodes bearing grafted enzymes, Biotechnol. Bioeng, vol.48, issue.21 37, pp.1877-79, 1679.
DOI : 10.1021/ac50006a014

D. R. Thevenot, R. Sternberg, C. , P. R. Thevenot, D. R. Sternberg et al., A glucose electrode using high stability glucose oxidase collagen membranes Phenomenes limitants dans les electrodes a enzymesJournees d'Electrochimie C : Progress toward a potentially implantable enzyme-based glucose sensor Implanting the glucose enzyme electrode: progress, problems, and alternative solutions Magnetic enzyme membranes as active elements of electrochemical sensors. Lactose, saccharose, maltose, bienzyme electrodes Improvement of glucose sensor performance with immobilized glucose oxidase-glucose isomerase system Prototype glucoseoxygen sensor for the artificial pancreas, Slama, G., and Sayler, D. F.: Continuous extracorporeal monitoring of animal blood using the glucose electrode, pp.518-545, 1975.

S. O. Enfors, N. N. Molin, J. Robson, and B. Fuller, Response characteristics of p H based enzyme electrodes for analysis of penicillin and glucose in fermentation broth T e s t i n g of t h e Yellowsprings Instrument Model 23 AM glucose analyser: A model for the amperometric enzyme electrode obtained through digital simulation and applied to the immobilized glucose oxidase system, Mell, L. D., and Maloy, J. T.: Amperometric response enhancement of the immobilized glucose oxidase enzyme system. Anal, pp.361-64, 1973.

C. Williams, D. Doig, A. Korosi, and A. W. , Electrochemical-enzymatic analysis of blood glucose and lactate On the role of substrate diffusion in enzyme electrodes, Anal. Chem. Experientia, vol.48, issue.18, pp.1597-1601, 1970.

G. Sensors-/, D. R. Thevenot, P. R. Coulet, R. Sternberg, D. R. Thevenot et al., Enzyme stabilization by immobilization, chemical study of reactions at interfaces of glucose oxidase collagen: Membrane-covered, ro-linkage of glucose oxidase on modified glassy carbon electrodes. Kitated disk electrode netic phenomena, Anal. Biochem. membranes. Biochim. Biophys. Acta Anal. Chem. J. Am. Chem. Soc, vol.93, issue.102, pp.53-54, 1979.